• FEATURES Performance characteristics as per NFPA 20 Complete unit responsibility. Complete in-house fabrication capabilities. Hydrostatic testing facilities. Operation run test as per NFPA 20. Horizontal Split case pumps for capacities up to 8000 USGPM. Drivers: Electric motor drive or diesel engine drive. Electrical testing capabilities for motors and controllers connected to fire pumps as per NFPA standards. Capable to supply additional accessories wherever required
  • FEATURES

    • Performance characteristics as per NFPA 20
    • Complete unit responsibility.
    • Complete in-house fabrication capabilities.
    • Hydrostatic testing facilities.
    • Operation run test as per NFPA 20.
    • Horizontal End Suction pumps for capacities up to 750 USGPM
    • Drivers: Electric motor drive or diesel engine drive.
    • Electrical testing capabilities for motors and controllers connected to fire pumps as per NFPA standards.
    • Capable of supplying additional accessories wherever required.
  • FEATURES 

    • Performance characteristics as per NFPA 20
    • Complete unit responsibility.
    • Complete in-house fabrication capabilities.
    • Hydrostatic testing facilities.
    • Operation run test as per NFPA 20.
    • Vertical Turbine models pumps for capacities up to 6000 USGPM.
    • Drivers: Electric motor drive or diesel engine drive.
    • Electrical testing capabilities for motors and controllers connected to fire pumps as per NFPA standards.
    • Capable of supplying additional accessories wherever required.
  • SPECIFICATION DIESEL ENGINE RANGES (SERIES: FD - R / FD - H / FD - HN / FD – HT / FD-Hi)
    Rated Output 10 HP - 500 HP
    Rated Voltage 380-400-415v (50Hz), 208-230v* (60Hz), 380-400v (60Hz), 440-460v (60Hz) & 575 (60Hz)
    Rated Speed 2923 - 2980 (50Hz) & 3506 - 3575 (60Hz)
    * These values only indicate the overall range available in this series. For the availability of any specific ratings and details of its certification, please contact the factory.
  • RATINGS SERIES: NM, TEFC ENCLOSURE 2 POLE
    Rated Output 10 HP - 500 HP
    Rated Voltage 380-400-415v (50Hz), 208-230v* (60Hz), 380-400v (60Hz), 440-460v (60Hz) & 575 (60Hz)
    Rated Speed 2923 - 2980 (50Hz) & 3506 - 3575 (60Hz)
    *Motors rated at this voltage are available only for power ratings from 15 to 100 Hp. 4 POLE
    Rated Output 10 HP - 400 HP
    Rated Voltage 380-415v (50Hz), 208-230v* (60Hz), 380-400v (60Hz), 460v (60Hz) & 575v (60Hz)
    Rated Speed 1460-1480 RPM (50Hz) & 1750 -1780 RPM (60Hz)
    ** Motors rated at this voltage are available only for power ratings from 15 to 100 Hp.
  • SPECIFICATION

    DC Voltage(VDC) Line Voltage(VAC) Enclosure Size(mm)
    12 220/110 900 (H) x 600 (W) x 300 (D)
    24 220/110 900 (H) x 600 (W) x 300 (D)
  • SPECIFICATION

    MODEL - STARTING TYPE

    • NFY-DOM1 - Direct On Line
    Motor Power (HP0 Rated Voltage (V) Frequency (Hz) Rated Circuit(A) Short Circuit(kA)
    15 380 - 415 50 / 60 27 100
    20 380 - 415 50 / 60 34 100
    25 380 - 415 50 / 60 44 100
    30 380 - 415 50 / 60 51 100
    40 380 - 415 50 / 60 66 100
    50 380 - 415 50 / 60 83 100
    50 380 - 415 50 / 60 103 100
    75 380 - 415 50 / 60 128 100
    100 380 - 415 50 / 60 165 100
  • RATINGS
    Power Rating 1.5 - 7.5 HP DOL Starter & 10 - 40 HP Star Delta Starter
    Voltage 230/380/415/480 V
    Frequency 50/60 hz
    FEATURES  ENCLOSURE OPTIONS: NEMA 2, NEMA 3, NEMA 4, NEMA 4x, NEMA 12 STANDARD FEATURES
    • Main disconnect switch with rotary handle, sized for disconnecting motor horsepower and voltage.
    • Motor Starter (DOL) or Overload Relay (Star-Delta) rated to the motor's horsepower, with thermal and short circuit protection.
    • Rated motor connectors.
    • Circuit breaker for protection of control circuit and motor.
    • Star—Delta starting timer. (in Model NFY-JSD1 & NFYJSD1-M1)
    • Power ON/Healthy indicator/free contact.
    • Pump Run indicator/free contact.
    • Pump Trip indicator/free contact.
    • Adjustable pressure switch.
    • Run Period Timer
    MODELS: NFY-JDO1 Direct On-Line & NFY-JSD1 Star-Delta. Selector switch for Hand-Off-Automatic Operation. NFY-JDO1-M1 Direct On-Line & NFY-JSD1-M1 Star-Delta
    • Touch control panel to operate, monitor, and set up the controller.
    • Automatic and manual selection on the touch panel screen.
    • Real-time voltage and pressure reading on screen.
    • Real-time pump running status, alarm details, and time delay on screen.
    • Password protection.
    • Screen saver mode.
    • Up to 4 auxiliary inputs and 3 output ports.
    • Up to 5 predefined options to select on input auxiliary.
    • Up to 24 predefined options to select on output auxiliary
  • FUEL TANK CAPACITY

    Type Cylindrical, Horizontal
    Fuel Tank Size 70 - 750 US Gallons
    1000 - 2000 US Gallons * *

    * * With Pad Plate & ladder

    FEATURES

    • Meets NFPA 30 requirements.
    • Sized as specified by NFPA 20 for fire pump applications.
    • Designed and Fabricated in accordance with UL 142 (Steel Aboveground Tanks for Flammable and Combustible Liquids) standard.
    • Tested for tightness against leakage.
    • Top quality fittings and fabrication materials.
    • Sturdy lifting lug and legs.
    • Vent opening to prevent build-up of pressure or vacuum inside the tank during filling, emptying or due to atmospheric temperature changes.
    • Approved welding process.